BCP-CO2 Gas detector
- The BCP-CO2 sensors can be easily integrated directly into the gas lines. It is possible to measure the carbon dioxide concentration in waste gasses from fermentations, independent of the gas flow.
- Additional gas coolers, pumps and valves are not needed to make the measurements. Fast and reliable measure data without a lot of maintenance are the result. With the aid of standard interfaces, the sensors can be connected to any process control system
- Measuring range: 0 to 10 CO2 Vol.%, 0 to 25 CO2 Vol.%, 0 to 50 CO2 Vol.%,
- Measuring principle: infrared, dual beam
- Accuracy: < ± 0,2 % FS ± 3% reading
- Long-term stability: < ± 2% reading / year
- Housing: Aluminum, IP 65
- Dimension / Weight: 100 x 100 x 130 mm W x D x H / 750 g
- Connection material: Steel 1.4571 / Sapphire / Viton / PTFE
- Connection: G 1 1/4 '', GL 45, TriClamp etc.
- Operating temperature: 5 to 30 °C, 15 to 40°C, 25 to 50°C
- Pressure range: 800 to 2000 mbar
- Pressure dependence: compensated, < ± 3 % reading (range)
- Operating humidity: 0 to 100% RH
- Power supply: 24 VDC, 1 A
- Output: RS 232, 4 to 20 mA
|
|
BCP-O2 Gas Detector
- The BCP-O2 sensors can be easily integrated directly into the gas lines. It is possible to measure the oxygen concentration in waste gasses from fermentations, independent of the gas flow.
- Additional gas coolers, pumps and valves are not needed to make the measurements. Fast and reliable measure data without a lot of maintenance are the result. With the aid of standard interfaces, the sensors can be connected to any process control system
- Measuring range: 0,1 to 25 O2 Vol.%, 1 to 40 O2 Vol.%
- Measuring principle: Zirconium dioxide (do not use in explosiv atmosphere)
- Accuracy: < ± 0,2 % FS ± 3% value
- Warm up: 30 minutes
- Housing: Aluminum, IP 65
- Dimension / Weight: 100 x 100 x 130 mm W x D x H / 750 g
- Mechanical connector: G 1 1/4 '', GL 45, TriClamp etc.
- Temperature range: 0 to 60 °C
- Pressure range absolute: 800 to 2000 mbar
- Humidity: 0 to 100% RH (under voltage)
- Power supply: 24 VDC, 1 A
- Output RS 232, 4 to 20 mA
- Lifetime: approx. 15.000 hours (under voltage)
|
|
BCP-CH4 Gas Sensor
- The BCP-CH4 sensors can be easily integrated directly into the gas lines. It is possible to measure the methane concentration in waste gasses from fermentations, independent of the gas flow.
- Additional gas coolers, pumps and valves are not needed to make the measurements. Fast and reliable measure data without a lot of maintenance are the result. With the aid of standard interfaces, the sensors can be connected to any process control system
- Measuring range: CH4 0 to 100 Vol.%
- Principle: Infrared, Dual wavelength
- Accuracy: < ± 0,2 % FS ± 3% reading
- Long-term stability < ± 2% reading / year
- Housing: Aluminum, IP 65
- Dimension / Weight: 100 x 100 x 130 mm W x D x H / 750g
- Material: Steel 1.4571 / Sapphire / Viton / PTFE
- Connection: G 1 1/4 '', GL 45, TriClamp etc...
- Operating temperature: 5 to 30 °C, 15 to 40°C, 25 to 50°C
- Pressure range 800 to 1300 mbar
- Pressure dependence: compensated, < ± 3 % reading (range)
- Operating humidity: 0 to 100% RH
- Power supply 24 VDC, 1 A
- Output RS 232, 4 to 20 mA
|
|
BCP-H2 Sensor
- The BCP-H2 sensors can be easily integrated directly into the gas lines. It is possible to measure the hydrogen dioxide concentration in waste gasses from fermentations, independent of the gas flow.
- Additional gas coolers, pumps and valves are not needed to make the measurements. Fast and reliable measure data without a lot of maintenance are the result. With the aid of standard interfaces, the sensors can be connected to any process control system
- Measuring range: H2 0 to 100 Vol.%
- Measuring principle: Thermal conductivity (WLD)
- Concentration range: 0,1 bis 100 Vol.%
- Accuracy: < ± (0,2% FS + 3% reading)
- Sensor temperature: +50 to +75 °C
- Gas flow 0 to 300 l/h
- Gas pressure (absolute): 0,4 to 2,5 bar
- LxWxH / Weight: 100 x 100 x 80 mm (IP65) / 1 kg
- Connection for gas: 6 mm
- Materials in contact with gas: Stainless steel, Si, SiOxNy, gold,epoxy, Acrylnitril-butadien-rubber, Viton
- Power supply: 24V DC, 600 mA
- Output: 4 - 20 mA, RS 232
- Output impedance: 250 Ohm
- Cross sensitivities: 10% CO2 -0,95% H2, 10% CH4 1,28% H2, 10% O2 0,12% H2
- Not usable in explosive atmospheres
|
|
BlueInOneFERM Gas Sensor
- parallel measurement of O2 and CO2
- compact stainless steel housing
- PAT conform in-situ- measurement
- auto compensated humidity and pressure
- no gas cooler, pumps or valves needed
- connectable to any hose/tube or pipe
- status display by luminous pushbuttons
Description of the O2 sensor
- Measuring principle: Zirconium dioxide
- Measuring range: 1 to 50 Vol.%
- Accuracy: < 0,2% FS ± 3% value
- Drift: < ± 2% value / year
- Lifetime of sensor element: 15 000 operating hours
- Temperature inside of the sensor unit: 580°C / 1076°F
- Output: Slope 0.32 mA / Vol.%, 4 mA = 0.0 Vol.%, 20 mA = 50.0 Vol.%
Description of the CO2 Sensor
- Measuring principle: Infrared, dual wavelength
- Measuring range: 0 to 10 Vol.%
- Accuracy: < 0.2% FS ± 3% value
- Drift: < ± 2% value / year
- Lifetime of optical components: approx. 3 years
- Temperature inside of the sensor unit: 3 °C / 5.4 °F higher than max. temperature
- Output: Slope 1.6 mA / Vol.%, 4mA = 0.0 Vol.%, 20mA = 10.0 Vol.%
General
- Temperature range: 15 - 40°C / 59°F - 104°F
- Pressure range: 0.8 to 1,3 bar / 11.6 to 18.85 psi
- Operating humidity: 0 to 100% RH
- Housing: Stainless steel, IP65
- Materials in contact with process gas: steel 1.4571, viton, sapphire, PTFE, Polymer H.L., nitrile, tygon
- Filters: PTFE 0,22 um, PTFE 5 um
- Power supply: 24V 1A
- Don't use in explosive atmosphere, in anoxic atmosphere, in gases with polymers or silicon components or in gases with halogens (F, Cl, Br), CFC or SOX and H2S
|
|
Software + Connection box
- The BACCom connection box is a converter box wich can be connected to a computer with a RS232 interface. Up to 8 sensors can be connected to one box.
- 2 softwares are available:
- 1. The software BacVis was made for data recording of different sensors and gas flow meter (milligascounter®).The sensors are recognized automatically by means of their identification number. Due to the easy handling, BacVis is self-explanatory. As the obtained data are recorded in the ASCI-format, you can process them without any problems.
- 2. The software FermVis for recording the concentration of CO2 and O2 during a fermentation with simultaneously calculation of the oxygen uptake rate (OUR), carbon dioxide emission rate (CER) and the respiratory quotient (RQ) in shake flasks and fermenters
|
|
Data Logger EL-USB-CO
- Carbon Monoxide (CO) Data Logger with USB Interface
- Measurement Range: 0-1000 ppm
- Accurency: ±6 % of reading
- Response time (to reach 90%): 1 minute
- Memory: 16,382 readings
- Logging rate:10 s to 5 min
- Operating temperature range: -10 to 40 °C
- Operating pressure range: 900 to 1100 mbar
- USB Interface for Set-up and Data Download
- Bright Red, Green and Orange LED Indication
- Replaceable Internal Lithium Battery
- 1/2 AA 3.6V Lithium Battery Life: 1 year
- It is not a suitable substitute for a domestic or industrial Carbon Monoxide detector/alarm
- The software is included
|
|
Transmitter for CO2, Relative Humidity and Temperature
EE80 series set new standards in CO2 measurements for HVAC (Heating, Ventilation and Air-Conditioning). The transmitters resp. switches combine CO2, relative humidity (RH) and temperature (T) measurement in one modern and user-friendly housing. The basic EE80 version for CO2 and T can be easily extended with a RH plug-in module. The CO2 measerument is based on the infrared principle. A patented autocalibration procedure compensates for the aging of the infrared source and ensures outstanding long term stability. EE80 provides analogue outputs (in V or mA). The optional display indicates sequentially the actual measuring data. As one more option a switching output with adjustable switching point and hysteresis is available.
- CO2 Measurement principle: Non-Dispersive Infrared Technology (NDIR)
- CO2 working range: 0 to 2000 or 0 to 5000ppm
- CO2 accuracy at 25°C and 1013 mbar, from 0 to 2000 ppm: < ± (50ppm +2% of measuring value), from 0 to 5000ppm: < ± (50ppm +3% of measuring value)
- CO2 response time: t63 < 195s
- CO2 Temperature dependence: typ. 2ppm CO2/°C
- CO2 long term stability: typ. 20ppm / year
- CO2 sample rate approx. 15s
- Temperature Accuracy at 20°C: ±0.3°C, for the version with current output 4 - 20mA: ±0.7°C
- Relative humidity measurement principle: capacitive
- Working range: 10 to 90% RH
- Accuracy at 20°C: ±3% RH (30 to 70% RH), ±5% (10 to 90% RH)
- Analogue Output: 0 to 2000 / 5000 ppm: 0 - 5V, 0 to 100% RH / 0 to 50°C: 0 - 10V,4 - 20mA RL < 500 Ohm
- Switching Output: ax. switching voltage 50V AC / 60V DC, max. switching load 0.7A at 50V AC 1A at 24V DC, Min. switching load 1mA at 5V DC, Contact material Ag+Au clad
- Supply voltage 24V AC ±20% 15 - 35V DC
|
|
CO2 Transmitters and Switches for demanding applications EE82
Measuring instruments in green houses or life stock barns are exposed to a very demanding environment: high humidity levels, pollutants like fertilizers, herbicides and high ammonia concentrations are just a few of the many hazards. The robust, functional housing of the EE82 with integrated special filter has been designed for such applications. The air diffuses through the filter into the instrument enclosure. Then the air diffuses further through a second membrane filter integrated in the CO2 measuring cell. The CO2 measurement is based on the non-dispersive infrared (NDIR) technology. The patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field. Measuring ranges of 0...2000/5000/10000ppm correspond to an analogue interface of 0 - 5/10V or 4 - 20mA. Selectively a switching output with adjustable switching point and hysteresis is available.
- Measuring principle: Non-Dispersive Infrared Technology (NDIR)
- Measuring range: 0 to 2000 / 5000 / 10000ppm
- Accuracy at 25°C and 1013mbar: 0 to 2000ppm: < ± (50ppm +2% of measuring value), 0 to 5000ppm: < ± (50ppm +3% of measuring value), 0 to 10000ppm: < ± (100ppm +5% of measuring value)
- Response time: τ63 < 195s
- Temperature dependence: typ. 2ppm CO2/°C
- Long term stability: typ. 20ppm / year
- Sample rate: approx. 15s
- Analogue Output: 0 to 2000 / 5000 / 10000ppm 0 - 5 / 0 - 10V, 4 - 20mA RL < 500 Ohm
- Switching Output: Max. switching voltage 50V AC / 60V D, Max. switching load 0.7A at 50V AC 1A at 24V DC, Min. switching load 1mA at 5V DC, Contact material Ag+Au clad
- Supply voltage 24V AC ±20% 15 - 35V DC
|
|
Data logger HUMLOG 20-TCO for humidity, temperature and CO2
The HUMLOG20 facilitates exact and professional recordings for climatic measurements of humidity, temperature, and CO2 concentration. The long battery life and large memory allow for continuous data recording over long periods of time. The configuration of the data logger and the evaluation of the measurement data are simple and straightforward using SmartGraph3 software, which is included in the scope of supply. The built-in Ethernet interface makes the HUMLOG20 Network capable, and ensures maximum reliability in data transmission.
- Relative Humidity Sensor: capacitive
- Relative Humidity Measurement range: 10 to 95%RH
- Relative Humidity Accuracy at 20°C: ±2%RH
- Relative Humidity Resolution: 0.1%RH
- Temperature Sensor: NTC
- Temperature Measurement range: -20 to 50°C
- Temperature Accuracy ±0.3°C (0 to 40°C), otherwise ±0.5°C
- Temperature Resolution: 0.1°C
- CO2 Sensor: NDIR 2-Beam Principle
- CO2 Measurement range: 0 to 5000 ppm
- CO2 Accuracy: ± (50ppm +3% of measured value)
- CO2 Resolution: 1 ppm
- CO2 Long-term stability: 20 ppm/year
- CO2 Response time: t90 < 195s for measurement rate 10s
- CO2 Temperature dependence: typ. 2ppm CO2/°C (0 to 50°C) different from 25°C
- Data storage: 16 MB, 3 200 000 measured values
- Battery lifetime: > 4 months
- Interface USB, LAN (Ethernet)
- Measurement rate 10/30s, 1/10/12/15/30min, 1/3/6/12/24h
- Storage rate 1/1012/15/30min, 1/3/6/12/24h
- Power supply Battery 4 x LRG AA Mignon or USB, optionally the power supply via PoE (Power over Ethernet) is possible
- Working range Temperature: -20 to 50°C
- Humidity: 0 to 95%RH (non condensing)
- LC-Display size 90x64 mm
- Dimensions: length 166 mm, width 78 mm, depth 32 mm
|
|
Modular CO2 transmitter for demanding applications EE870
The interchangeable CO2 probe incorporates the dual wavelength NDIR CO2 sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability. Multiple point CO2 and temperature adjustments lead to excellent measurement accuracy over the entire temperature working range, ideal for use in agriculture and outdoors.
The IP65 enclosure and the replaceable PTFE filter offer excellent protection in harsh, polluted environments. The compact size, the M12 connector and the optional mounting flange allow for fast probe installation or replacement. An optional kit facilitates easy configuration and adjustment of the probe.
The measured data range of up to 10000ppm is available on the analog outputs. Several voltage and current ranges can be selected with jumpers. Additionally, the data is available on the Modbus RTU interface, which can be configured by the user with DIP switches on the board.
- Measuring range: 0 to 2000 / 5000 / 10000 ppm
- Outputs: 0-1V, 0-5V, 0-10V, 0-20mA, 4-20mA and Modbus RTU
- Accuracy: 0 to 2000ppm: ±(50ppm +2% of measuring value), 0 to 5000ppm: ±(50ppm +3% of measuring value), 0 to 10000ppm: ±(100ppm +5% of measuring value)
- Temperature dependency: typ. 1ppm CO2/°C (-20...45°C)
- Supply 10 to 35V DC / 10 to 28.8V AC
|
|
Digital CO2 Sensor Module EE893
A multiple point CO2 and temperature adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range; this is a must for process control and outdoor applications. The dual wavelength NDIR CO2 sensing procedure compensates automatically for ageing effects. EE893 is highly insensitive to pollution and offers outstanding long term stability. With its small dimensions and electrical connection via contact pins and pads, EE893 is the optimal choice for devices such as wireless transmitters, hand-helds or data loggers. The measured data, with a range of up to 10000ppm, is available on the E2 digital interface. An optional kit facilitates easy configuration and adjustment of the probe. The measurement interval can be set according to the application requirements; by this the average current consumption can be reduced to less than 60μA for battery-operated devices.
- Measurement principle: Dual wavelength (non-dispersive infrared technology) NDIR
- Working range: 0 to 2000 / 5000 / 10000ppm
- Accuracy at 25°C and 1013mbar: 0 to 2000ppm: < ± (50ppm +2% of measuring value), 0 to 5000ppm: < ± (50ppm +3% of measuring value), 0 to 10000ppm: < ± (100ppm +5% of measuring value)
- Response time: t90 < 60s or < 105s; (depending on the measured value)
- Temperature dependency: typ. 1ppm CO2/°C (-20...45°C)
- Calibration interval: >5 years
- Measuring time interval adjustable from 15s up to 1h (factory setting: 15s)
- Digital interface E2
- Supply voltage 4.75 - 7.5V DC
|
|
PMC - gas detector
mesurement principle: diffusion
supply voltage: 12-30 VDC
output: 4-20 mA or RS485 (modbus)
available gas
|
range |
zero gas |
Acetylene (C2H2) |
0 - 2.3 % vol |
air |
Butene (C4H10) |
0 - 1.4 % vol |
air |
Ethylene (C2H4) |
0 - 2.4 % vol |
air |
Ethylene (C2H4) |
0 - 2000 ppm |
air |
CO2 |
0 - 5000 ppm |
N2 |
CO2 |
0 - 2 % vol |
N2 |
CO2 |
0 - 5 % vol |
N2 |
CO2 |
0 - 10 % vol |
N2 |
CO2 |
0 - 20 % vol |
N2 |
CO2 |
0 - 30 % vol |
N2 |
CO |
0 - 2 % vol |
N2 |
Methane (CH4) |
0 - 4.4 % vol |
air |
|
|
smartMODUL for Biogas - CO2/CH4 gas detector
Infrared gas sensor using dual beam technology, with measurement and reference channel, for the use in process control systems in biogas applications. Integrated evaluation electronics for drift and temperature compensation. Optimized gas-calibration for measuring methane and carbon dioxide in biogas. Robust aluminum cuvette with gas line connector.
- Non Dispersive Infra-Red (NDIR), dual wavelength
- Flow rate: 0.2 to 0.8 l/min (constant)
- Warm-up time: < 2 minutes (start up time), < 30 minutes (full specification)
- Response time (t90): Appr. 15 s (@ 0.5 l/min)
- Detection Limit (3 s): < 1.5 % FS (typically)
- Linearity error (4): < ± 2 % FS
- Operating temperature: -20 °C to 40 °C
- Air pressure: 800 to 1200 hPa
- Digital output signal: Modbus ASCII via UART
- Also available with a wider supply voltage range of 12 - 28V DC, analog signal output 0 (4) - 20 mA and digital output RS 485.
available gas
|
range |
CO2, ref. F1-214507-00900 |
0 - 50 % vol |
CO2, ref. F1-214108-00900 |
0 - 100 % vol |
CH4, ref. F1-043507-00900 |
0 - 50 % vol |
CH4, ref. F1-043108-00900 |
0 - 100 % vol |
|
|
Carbonoxy - O2/CO2 gas detector
- O2 principle of operation: Zirconia
- O2 measurement range: 0-25, 0-95 % vol
- O2 accuracy: < ±0.5 %FS
- CO2 principle of operation: NDIR
- CO2 measurement range: 0-10, 0-30 % vol
- CO2 accuracy: < ±2 %FS
- Response time T90: 1 or 30 sec adjustable
- Operating temperature: -10 to +45°C
- Warm-up time: 2min
- Operating humidity: 0 to 98% r.h. (non-condensing)
- Power supply: 11.5 to 30 VDC
- Power consumption: 6W
- Outputs: 2 x 0/4 to 20mA, 0/2 to 10VDC, RS232/19 200 Baud
- Life span: >3 years
- Flow rate: 0.5 to 1 l/min
- Dimensions: 160 x 100 x 40mm
- Weight: 380gr
|
|
Oxygen module with a Zirconia Sensor FCX-MC25-CH & FCX-MC95-CH
The sensor is either mounted directly on the control board, with or without a flow housing, or remote from the control board via cables.
- 0 to 25 % or 0.1 to 95% O2
- No reference gas is needed
- Lifetime >30'000 operation hours
- Sensor temperature is about 450 °C
- No calibration needed
- Excellent longtime stability
- warmup time: about 3 min
- Low power consumption
- Analog output: 0/4 to 20mA, 0 to 10VDC linear
- Digital output: RS485/RS232
- RoHS/Reach conform
|
|
Oxygen module with a Zirconia Sensor FCX-ML05H-CH & FCX-ML25-CH & FCX-ML95-CH
The sensor is either mounted directly with a flow housing, or remote from the control board via cables.
- 0 to 5 %, 0 to 25% or 0.1 to 95 % O2
- No reference gas is needed
- Lifetime >30'000 operation hours
- Sensor temperature is about 450 °C
- No calibration needed
- Excellent longtime stability
- Low power consumption
- Analog output: 0/4 to 20mA logarithmic
- RoHS/Reach conform
|
|
Gas detector THA100S
is used to analyze the concentration of CO, CO2, CH4, SO2, NO.
- Principle: IR
- Temperature of operation: 5 to 45 °C
- Stability: ±1%FS / 7 days
- Repeatability: 0.5%
- Linearity: ±1 % FS
- Response time (T90): 15s (infrared)
- Influence of environment temperature: ± 1 % FS (5 to 45 °C)
- Influence of interference error: ± 1% FS
- CO range: 0-2000 ppm
- CO2 range: 0-1000 ppm
- CH4 range: 0-1%
- NH3 range: 0-1%
- SO2 range: 0-500 ppm
- NO range: 0-1%
- NO2 range: 0-5%
- MN range: 0-5%
- SF6 : 0-500 ppm
- The gas composition should be know at the order.
|
|
O2 Gas detector Oxymeter
it measures the concentration of the O2 in outgas/exit gas in fermentation processes.
in combination with the Software Lea, it is possible to calculate the OUR, CPR and RQ.
Technical specifications
- O2 concentration range: 0 - 9.99% or 10.0 - 25%
- O2 partial pressure (ppO2): 0 - 250 mBar
- Pressure range: 500 - 1200 mBar
- Temperature range: 0 - 60 °C
- Accuracy: 2% of the concentration range
- Power supply: 12V/6W
- Dimension: 105 x 80 x 170 mm (W x H x D)
- Weight: 600 g
- Serial interface (RS232 or RS485)
|
|
CO2 Gas detector Carbometer
it measures the concentration of the CO2 in outgas/exit gas in fermentation processes.
in combination with the Software Lea, it is possible to calculate the OUR, CPR and RQ.
Technical specifications
- CO2 concentration range: 0 - 9.99% or 10.0 - 99.9 %
- Accuracy: 3% of the concentration range
- Power supply: 12V/6W
- Dimension: 105 x 80 x 170 mm (W x H x D)
- Weight: 600 g
- Serial interface (RS232 or RS485)
|
|
HY-OPTIMA 2700 Series Explosion Proof In-line Hydrogen Process Analyzer
The HY-OPTIMA(TM) 2700 Series uses a solid-state, non consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases. The HY-OPTIMA (TM) 2700 Series is ideal for applications where real-time, hydrogen specific measurements can enhance process plant efficiencies, diagnostics and maintenance management.
- Verification Interval: 90 days
- Product Life Expectancy: 10 Years
- Field Calibration: Yes
- Pressure Compensation: Yes
- Operating Humidity: < 95% RH (non condensing)
- Flow Rate: 0.1 to 10 slpm
- Process Gas Temperature:-20°C to 60°C
- Operating Temperature:-20°C to 55°C
- Storage Temperature:-30°C to 80°C
- Analog Output Signals: 4 to 20mA (or user specific mA)
- Serial: RS232 or RS422
- Relay Contacts: 2, 5A/240 VAC or 5A/30 VDC
- Input Voltage: 90 to 240 VAC
- Input Power: 15W
- Adapter Fitting: 3/4 in Union Tee Compression
|
|
Wireless CO2 datalogger Newsteo LGG43
LGG43 containment logger controls indoor air quality in buildings. I is a battery-powered wireless data logger that captures and analyses CO2 concentration with advanced Non Dispersive Infrared technology (NDIR) sensor. A compensation with pressure is performed.
- For air quality measurement
- Wireless transmission
- Industrial robust casing
- Several years autonomy on battery
- CO2 Range 0 to 5000 ppm
- Accuracy +/- 50 ppm
- Pressure Range 300 to 1100 hPa
- Accuracy +/- 1hPa
- Temperature Range -25°C to 55 °C
- Accuracy +/-0.3°C (5 to 55°C range)
- Humidity Range 0 to 95%
- Accuracy +/- 3% (20 to 50°C range)
- Sampling Rate from 1 min to 4 hours
- Memory Size 32256 measures
- Power Li-thy AA type (or Alkaline as option)
- RF 868MHz Wireless European certification
- Range ½ wavelength whip antenna
- Go thru several walls and floors
- Software Compliant With all NEWSTEO monitoring receivers and software's
|
|
Wireless CO2 datalogger PBCO2
- Connection type MiniJack
- Measurement range 400 - 2000 ppm
- Measurement precision ±50 ppm +/- 3% of
- Calibration with fresh air once per week
- Size 135 x 4 mm (LxD)
- Wire length 15 cm
- Operating temperature 0°C to 50°C
- Storage temperature -30°C to +70°C
- Host battery life Approx. 6 month
- Ref. SN001A-PRO
|
|
Gaz analyser QGA
This gas analyser is based on a mass spectrometer.
Multiple Gas and Vapour Analysis
200 amu mass range, 300 amu option.
2 metre continuous sampling heated capillary inlet.
Gas sample flow rate 16 atm. cc/min standard. 1 atm. cc/min option.
Gas sample pressure range: 100 mbar to 2 bar absolute. 1 mbar to 30 bar sampling options.
detection level: 100 % to 100 PPB.
<300 ms response time to changes in gas concentrations.
Fast data acquisition: up to 500 measurements per second.
Integrated CO analyser option for the analysis of low level CO in the presence of N2 and CO2.
Soft ionisation for reduced spectral fragmentation and simplified data interpretation.
Broad range of sampling accessories available.
|
|
CO2 and Temperature Transmitter for Duct Mounting E850
The EE850 is designed for use in building management applications. A multiple point CO2 and temperature factory adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range. The EE850 incorporates a dual wavelength NDIR CO2 sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.
Installed into a duct, a small amount of air will flow through the divided probe into the transmitter housing, where the CO2 sensing cell is located, and back into the duct.
The temperature sensor is located inside the probe.
- Measurement principle: dual wavelength non-dispersive infrared technology (NDIR)
- Measuring range: 0 to 2000 / 0 to 5000 / 0 to 10000 ppm
- Accuracy at 25 °C (77 °F) and 1013 mbar (14.7 psi) :
- 0 to 2000 ppm: < ± (50 ppm +2% of measured value)
- 0 to 5000 ppm: < ± (50 ppm +3% of measured value)
- 0 to 10000 ppm: < ± (100 ppm +5% of measured value)
- Response time: T63 < 100 s at 3 m/s (590 ft/min) air speed in the duct
- Calibration interval >5 years
- Sample rate : approx. 15 s
- Temperature Working range: -20 to 60 °C
- Analogue Output: 0 - 5 / 0 - 10 V / 4-20 mA possible
|
|
|