Sysmatec

Refractometer

refractometer

Manual refractometer

It is a device for the measurement of the index of refraction (refractometry). This index depends on the concentration of solute in a solution. So by measuring the refraction index it is possible to know the concentration of a substance in a solution.

It si possible to measure the concentration of product such alcohol, sugar, quality of oil, salt, milk,...

Series Model Range Accuracy
Brix/ATC VBR10T 0 to 10% 0.1%
VBR18T 0 to 18% 0.1%
VBR20T 0 to 20% 0.1%
VBR32T 0 to 32% 0.2%
VBR50T 0 to 50% 0.5%
VBR62T 28 to 62% 0.2%
VBR82T 45 to 82% 0.5%
VBR92T 58 to 92% 0.2%
VBR80 0 to 80% 0.5%
VBR90A 0 to 90% 0.5%
Alcohol/ATC SAL0080 0 to 60%, 60 to 80% V/V 1%, 2%


refractometer

Manual refractometer with LED

With built-in bright LED Light, which allows to measure the refraction index in the dark.

Easy replacement of the battery

By pressing the button the led will light will turn on. By pressing the button again the light turns off.

The Light is compatible with the most refractometers and can be ordered separatly (only change the plate)

5 colors: blue, black, red, green, purple (led light is white).

This product is also available without LED.

Series Model Range Resolution
Brix/ATC RHB-05 0 to 5% Brix 0.1%
RHB-10 0 to 10% Brix 0.1%
RHB-18 0 to 18% Brix 0.1%
RHB-20 0 to 20% Brix 0.1%
RHB-32 0 to 32% Brix 0.2%
RHB-50 0 to 50% Brix 0.2%
RHB-55 0 to 55% Brix 0.2%
RHB-62 28 to 62% Brix 0.2%
RHB-82 48 to 82% Brix 0.2%
RHB-92 58 to 82% Brix 0.2%
RHB0-80 0 to 80% Brix 0.5%
RHB0-90 0 to 90% Brix 0.5%
Honey RHB-90 58 to 90%, 38 to 43 Be, 12 to 27 % Water 0.5% Brix, 1 % Water, 0.5 % Be
RHB-92T 58 to 92%, 38 to 43 Be, 12 to 27 % Water 0.5% Brix, 1 % Water, 0.5 % Be
RHF-30 10 to 30 % Water 0.1 % Water
Salinity RHS-4 2 to 4 % , 1.015 to 1.030 RI 0.1 %, 0.001 sg
RHS-40 0 to 4 % , 1.000 to 1.030 RI 0.1 %, 0.001 sg
RHS-10 0 to 10 % , 1.000 to 1.070 RI 0.1 %, 0.001 sg
RHS-28 0 to 28 % 0.2 %
Car RHA-200 E:-60 to 0 °C, P:-50 to 0 °C, B:1.10 to 1.40 sg 5 °C, 0.01 sg
RHA-402 E:-50 to 0 °C, P:-50 to 0 °C, B:1.15 to 1.30 sg 5 °C, 0.01 sg
RHA-403 E:-50 to 0 °C, P:-50 to 0 °C,C:-40 to 0 °C, B:1.15 to 1.30 sg 5 °C, 0.01 sg
RHA-503 E:-50 to 0 °C, P:-50 to 0 °C,C:-40 to 0 °C, B:1.10 to 1.40 sg 5 °C, 0.01 sg
RHA-701 AddBlue: 30 to 35 %, B:1.10 to 1.40 sg 5 °C, 0.01 sg
RHA-801 Urea: 0 to 40 % 0.2 %
Wine RHW-80v Alcohol 0-80 % v/v 1 % v/v
RHW-25Brix Alcohol 0-25 % vol, 0 to 40 Brix 0.2 % v/v, 0.2 % Brix
RHW-25Vol Alcohol 0-25 % vol, 0 to 170 Oe 0.2 % v/v, 1 Oe
RHW-22Be 0 to 22 Baume, 0 to 25 % vol, 0 to 40 Brix 0.2 % v/v, 0.2 Brix, 0.2 % Baume
RHB-32S 0 to 140 Oe, 0 to 27 KMW(Babo), 0 to 32 Brix 1 Oe, 0.2 KMW, 0.2 % Brix
RHW-44S 0 to 190 Oe, 0 to 38 KMW(Babo), 0 to 44 Brix 2 Oe, 0.2 KMW, 0.5 % Brix
Clinical RHC-200 0 to 12 g/l, 1.000 to 1.050 sg, 1.3300 to 1.3600 RI, urine 0.2 g/dl, 0.005 sg, 0.0005 RI
RHC-300 2 to 14 g/l, 1.000 to 1.060RI, dog + cat 0.2 g/dl, 0.001 RI
Beer RHB-32SG-1 0 to 32 % Brix, WortSG: 1.100 to 1.120 0.2 Brix, 0.001 SG
RHB-32SG-2 0 to 32 % Brix, WortSG: 1.100 to 1.130 0.2 Brix, 0.001 SG
RHB-18P 0 to 18 ° Plato 0.1 ° Plato

E: Ethylen Glycol, P: Propylene Glycol, B: Battery fluid, C: Cleanig fluid, sg: specific gravity, RI: refraction index


refractometer

Digital refractometer Serie D

Model Parameter Range Accuracy
DBR0045 BRIX 0-45% 0.1
REFRACTLYINDEX 1.3330-1.3900 0.0003
DBR2865 BRIX 28-65% 0.1
REFRACTLYINDEX 1.3800-1.4535 0.0003
DBR5892 BRIX 58-92% 0.1
REFRACTLYINDEX 1.4370-1.5090 0.0003
DWN-1 MASS S/W 0-35% 0.1
VOL AP 0-22% 0.1
Oe(Swiss) 0-150 1
KMW 0-25 0.1


refractometer

Brix Measurement by Density or Sound Velocity

BRIX MONITOR is a variant of RHOTEC or SONATEC and allows measuring sugar content in liquids that don't contain any alcohol, e. g. in syrups and soft drinks. The instrument uses the functionality of either RHOTEC (density measurement) or SONATEC (sound velocity measurement) and is designed for applications requiring maximum sensitivity and highest accuracy. It is easy to operate and maintenance-free. The density measurement is based on the oscillating U-tube principle. For sound velocity measurement a sound pulse is created by a sonic transmitter and detected by a sonic receiver. As a specific property of each liquid, the correlation between concentration and density resp. sound velocity can be described by a mathematical polynomial. With decades of experience the polynomials for a large number of products are now known. Any temperature drifts of the measured signal are automatically compensated for.

Measuring Range 0 - 80 °Brix
Accuracy ± 0.03 °Brix (RHOTEC), ± 0.07 °Brix (SONATEC)
Product Temperature -5 to + 80 °C
Response Time <= 1 s
Pressure max. 16 bar
Material 1.4404/1.4435/AISI 316L; Hastelloy; Tantalum; etc.
Input 6 x digital (24 VDC)
Output 3 x digital (24 VDC) & 2 x analog (4 - 20 mA)
Profibus DP Option
Protection IP65
Power Supply 24 VDC


Contact

Top

Sysmatec
Oberdorfstrasse 51
CH 3930 Eyholz
tel + 41 27 946 80 18
fax + 41 27 946 86 42
info@sysmatec.ch