Vacuum filtration system N1650

Made only of fluoroplastics (PTFE/PFA) - without any sealing materials. These vacuum filters are resistant to virtually all chemicals and do not release any trace elements into the filtrate. The filtering membrane is easily interchangeable after disassembly of the sample funnel. A multi-stage hose connector with sleeve nut used as a vacuum connector is adapted to the most common vacuum tubings. The PFA lid on top of the sample funnel prevents contamination of the samples. The non-adhesive surfaces of the fluoroplastics (PTFE/PFA) allows easy cleaning of these vacuum filters. Thus, they have a long working life.

Table: Filtration flow rate for different pore sizes (PTFE membrane, differential pressure 100 kPa)

for a 47 mm diameter membrane with 0,2 mm thickness

Pore size (µm) flow rate (ml/min)
1 510
0.45 148
0.2 57

for a 90 mm diameter membrane with 0,2 mm thickness

Pore size (µm) flow rate (ml/min)
1 1638
0.45 369
0.2 121

Model (supplied without filtering membrane)

Reference Membrane diameter Filtration surface Capacity Total height Ext. diameter
N1650-8 47 mm 13.8 cm2 240 ml 250 mm 86 mm
N1650-16 47 mm 13.8 cm2 500 ml 290 mm 100 mm
N1650-24 90 mm 55.4 cm2 1000 ml 370 mm 130 mm


Vacuum filtration

Vacuum Adaptor with Ground Joint, PTFE

For vacuum filtration, the O-ring at the pass-through provides good sealing to the filter funnel. A slight vacuum is sufficient.

Temperature resistance: from -15°C to +200°C

Chemical resistance: very good

Can be autoclaved at 121°

Vacuum: suitable

Reference Cone size NS For funnel outlet max. Ø mm Hose Connectors O.D. 1 / O.D. 2
N1655-04 29/32 22 9/12
N1655-06 40/45 22 9/12


Filter adapter for syringe

Made only of fluoroplastic - without any sealing materials. These filter adaptors for syringes are resistant to virtually all chemicals and do not release any trace elements into the filtrate. The filtering membrane is easily interchangeable after disassembly of the filter adaptor. All these filter adaptors have a very low dead-volume and they can easily be cleaned due to their extremely smooth PTFE surface. Further advantages are: suitable for sterilization and metal-free. These filter adaptors provided with Luer Lock connectors on both sides can be screwed together into multi-stage filters (prefilter, main filter). The non-adhesive surface of the fluoroplastic (PTFE) allows easy cleaning of these filter adaptors. Thus, they have a long working life.

Table: Filtration flow rate for different pore sizes (PTFE membrane, differential pressure 150 kPa)

for a 13 mm diameter membrane with 0,2 mm thickness

Pore size (µm) flowrate (ml/min)
1 25
0.45 10

for a 25 mm diameter membrane with 0,2 mm thickness

Pore size (µm) flowrate (ml/min)
1 155
0.45 35

Model (Supplied without filtering membrane and without syringe)

Reference Membrane diameter Filtration area Height Ext. diameter
N1666-8 13 mm 0.78 cm2 35 mm 21 mm
N1666-16 25 mm 3.80 cm2 40 mm 34 mm


Filtration system

Made only of fluoroplastic - without any sealing materials exposed to the medium. These flow filters are suitable for vacuum and pressure above atmospheric, resistant to virtually all chemicals and do not release any trace elements into the filtrate. Made of PTFE, these flow filters withstand temperatures up to max. 160°C. The filtering membrane is easily interchangeable after disassembly of the flow filter. Further advantages are: suitable for sterilization and metal-free. Assembly is done by a laboratory screw joint system which is based on two-part V-rings. This system assures an absolutely tight connection with fluoroplastic tubing or with plastic, glass or metal tubes under vacuum or overpressure. Due to a variety of connecting possibilities these flow filters can be used as a large area in-line apparatus, for installation into lines and in combination with a pump as an added filter for the liquid supply. The non-adhesive surface of the fluoroplastic (PTFE) allows easy cleaning of these flow filters. Thus, they have a long working life.

Table: Filtration flow rate for different pore sizes (PTFE membrane, differential pressure 100 kPa)

for a 25 mm diameter membrane with 0,2 mm thickness

Pore size (µm) flowrate (ml/min)
1 96
0.45 11

for a 90 mm diameter membrane with 0,2 mm thickness

Pore size (µm) flowrate (ml/min)
1 648
0.45 264

Model (Supplied without filtering membrane)

Reference for membrane-Ø Filter area Thread for tubing with outside Ø
N1670-8 25 mm 3.1 cm2 GL14 3.2 mm and 6mm
N1670-16 47 mm 13.8 cm2 GL18 6 and 8 mm
N1670-24 90 mm 52 cm2 GL25 8 and 10 mm


Filtration System

Samplicity(TM) Filtration System

  • convenient, high throughput alternative to syringe-tip filters when preparing samples for chromatography
  • vacuum-driven system to filter 1 to 8 samples directly into standard HPLC vials
  • Just attach a vacuum pump, load samples with a standard pipettor, and flip the lever to recover particulate-free samples—even those with high viscosity or particulates—in seconds. In addition, the system has a low hold-up volume, which allows processing of samples as small as 300 µL
  • available in 2 different colors
  • filters material: hydrophilic PTFE
Reference Pore size (µm) amount
SAMPLG001 0.20 96/pack
SAMPLCR01 0.45 96/pack
SAMPLG004 0.20 384/pack
SAMPLCR04 0.45 384/pack