OxiDirect BOD-Measurement-System

BOD-Measurement-System

Categories: ,

Description

  • Direct and Accurate BOD, 1-28 days measurements, Mercury-free
  • Direct sample selection
  • Accurate and direct display of BOD values in mg/l
  • User-friendly handling
  • User-selectable measuring period from 1 to 28 days (BOD5, BOD7, OECD…)
  • Automatic storage of BOD values
  • Measuring ranges from 0-40 mg/l to 0-4000 mg/l BOD / sample volume related
  • Automatic start function following temperature equalisation of the samples
  • Mercury-free, environmentally-friendly BOD determination
  • Inductive stirring system with automatic
  • re-centering of stirring rods
  • Interface RS 232

Respirometric methods provide direct measurement of the oxygen consumed by microorganisms from an air or oxygen-enriched environment in a closed vessel under conditions of constant temperature and agitation. Carbon dioxide produced metabolically by the bacteria is chemically bound by the potassium hydroxide solution contained in the seal cup in the bottle.

The result is a pressure drop in the system, which is directly proportional to the BOD value and is measured by the BOD sensor. The BOD level is then displayed directly in mg/l.

The BOD values are stored in the sensor memory and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem.

The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days – and manometric determination of OECD, for example, generally takes place over a period of 28 days.

Automatic start function: variations in sample temperature prior to testing result in pressure variations within the measuring system during the temperature equalisation period in the thermostatically controlled cabinet (if BOD measurement is to take place at 20°C, for example). Such variations would normally cause errors during manometric measurement. In order to prevent such errors, the Lovibond® OxiDirect® BOD meter is equipped with an automatic start feature: measurement does not commence until the temperature in the samples is the same as that in the thermostatically controlled cabinet. This rules out the possibility of temperature (and hence pressure) fluctuations that are not related to the manometric measurement.

The complete BOD measuring system: In addition to the BOD unit for measurement and storage of BOD levels, the OxiDirect® BOD measuring system includes sample bottles, measuring sensors, non-wearing inductive stirring system, overflow measuring flasks for metering of sample volumes, nitrification inhibitor and potassium hydroxide as an absorbent.