Description
This is an innovative probe which transcends conventional limitations, bringing together ISFET pH sensing, 4-electrode conductivity measurement, and ORP (redox potential) analysis in a single device. The multiparameter probe ISFET pH/EC/ORP/T is an all in one single device. It is wireless, glass-free, robust. It can be stored dry.
The probe is wirelessly connected via Bluetooth to the Sentron app for setting configurations, acquiring, storing, and exporting all your measurement data.
ISFET pH sensor
Experience the future of pH measurement with our robust ISFET technology. Built for the knowledgeable, this sensor guarantees accurate readings in the most demanding applications. Precision and durability converge to supply pH readings in the harshest conditions, making fragile glass electrodes obsolete.
4-Electrode conductivity sensor
Dive into outstanding conductivity analysis with our advanced 4-electrode sensor. Minimize interference for precise results, elevating your understanding of water or moisture composition to new heights
ORP monitoring
Unparalleled accuracy in ORP assessments is provided by the 4-electrode sensor, coupled with the versatile reference electrode compatible for ISFET measurements. This dual-functional system ensures reliable and precise results, catering to diverse analytical needs
The sensor can be provided in a case with calibration solutions, a smartphone or a tablett. The probes communicate with Bluetooth with de device.
Cloud application
Eeasy and intuitive application, compatible to Android, Harmony OS and iOS
Calibration, acquisition, visualization, storage and export of measurement data;
Up to 6 connectable probes for simultaneous wireless measurements;
Real-time notifications whenever the pH value is out of reach;
GPS location based pH map in Google maps;
Language English, Dutch, Spanish, French, Chinese, Russian, Japanese, Swedish, Korean;
Free downloadable in GooglePlay, Huawei App Gallery, AppStore
ConeFET pH/EC/ORP/T | LanceFET pH/EC/ORP/T | |
Ref. | 3380-200 | 2370-200 |
for general purpose | Steel tipped pH/EC/ORP/T probe for easy penetration of firm samples (e.g. meat, fruits, ground) | |
general fluids (low viscosity) | general fluids (low viscosity) | |
Semi fluids (low to medium viscosity) | Semi fluids (low to medium viscosity) | |
Pastes and semi solids (medium to high viscosity) | Pastes and semi solids (medium to high viscosity) | |
General beakers and containers | General beakers and containers | |
Piercing applications (normal to medium force penatration) | ||
Conductivity range | 50 to 111 800 µS/cm | 50 to 111 800 µS/cm |
Sensor type | 4-electrode EC sensor | 4-electrode EC sensor |
Cell constant K (typical) | 3.89 cm-1 | 3.89 cm-1 |
Accuracy | 1 % from50 to 12 880 µS/cm, 10 % outside | 1 % from50 to 12 880 µS/cm, 10 % outside |
Resolution | 0.5 nS/cm from50 to 12 880 µS/cm, 50 nS/cm outside | 0.5 nS/cm from50 to 12 880 µS/cm, 50 nS/cm outside |
Drift typical (in 1,413 µS/cm EC standard @ 25°C) |
2.5 µS/cm / day | 2.5 µS/cm / day |
Calibration | at factory / 1-point calibration | at factory / 1-point calibration |
Automatic temperature compensation (ATC) | yes | yes |
Calibration standards | 500 μS/cm, 1 413 μS/cm, 12 880 μS/cm |
500 μS/cm, 1 413 μS/cm, 12 880 μS/cm |
Oxidation Reduction range | -2.000 to +2.000 mV | -2.000 to +2.000 mV |
Accuracy | ±0.2mV | ±0.2mV |
Resolution | 0.1 mV | 0.1 mV |
Calibration | at factory | at factory |
pH range | 0 to 14 | 0 to 14 |
Accuracy | +/- 0.02 pH | +/- 0.02 pH |
Resolution | 0.01 pH | 0.01 pH |
Drift maximal (in pH7 @ 25°C) | 0.14 pH/day | 0.14 pH/day |
Calibration | 1-, 2-, 3- and 5-point calibration | 1-, 2-, 3- and 5-point calibration |
Automatic temperature compensatio(ATC) | yes | yes |
Calibration buffer types | Sentron buffers, DIN, NIST, JIS | Sentron buffers, DIN, NIST, JIS |
Temperature range | 0 to 80 °C | 0 to 80 °C |
Resolution | 0.1 °C | 0.1 °C |
Accuracy | 1% | 1% |
Sensor | NTC | NTC |