Features

LOD (limit of detection) μg/L MRL (maximal residue limit) μg/L
Gentamycin 2-3 100
Neomycin 2-3 500
Kanamycin 2-3 150
Spectinomycin 1-2 200

Operations

a) Read the instructions before experiment. Bring the test kit and samples to room temperature. Milk samples should be fully liquid without any agglomeration and deposition.
b) Take out required wells and strips from the package, and make proper marks. Please use the test strips within 1h. Seal the cap of the bottles and store the rest of the unused kit.
c) Take 200ul of the milk sample into the microwell, then repeatedly absorb up and down for 5 times to mix the sample with the reagent in the wells completely. The mixture should be pink, and then start the timer. Note: In case you are sampling with plastic pipet, please add sample to the MARKER LINE on the microwell.
d) Incubate for 3min at room temperature (20-25oC), and then insert the test strip into the well with the “Immersed” end fully dipped in to the mixed reagent and sample.
e) Incubate for 7min at room temperature (20-25oC). Take out the strip; determine the result

Results

Gentamycin Positive: Compare the color of Line T1 with Line C, if the color of Line T1 is lighter than or the same as Line C, the result will be positive. If there is no Line T1, the result is also positive.
Neomycin Positive: Compare the color of Line T2 with Line C, if the color of Line T2 is lighter than or the same as Line C, the result will be positive. If there is no Line T2, the result is also positive.
Kanamycin Positive: Compare the color of Line T3 with Line C, if the color of Line T3 is lighter than or the same as Line C, the result will be positive. If there is no Line T3, the result is also positive.
Spectinomycin Positive: Compare the color of Line T4 with Line C, if the color of Line T4 is lighter than or the same as Line C, the result will be positive. If there is no Line T4, the result is also positive.